Home » Files » Products/Inventions |
Sievers 5310 C Series TOC Analyzers Specifications, Applications, Features and Benefits
2011-May-19, 5:31 PM | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Overview The Sievers* 5310 C Series Total Organic Carbon (TOC) Analyzers were designed specifically for the municipal drinking wate market. They offer superior accuracy and precision across a dynamic operating range of 4 parts per billion (ppb) to 50 parts per million (ppm) TOC. ![]() Picture of GE (General Electric) Sievers 5310 C Series TOC Analyzers The 5310 C TOC Analyzers were engineered for ease of use and cost-effective operation. They offer automated procedures such as calibration, verification, reagent adjustment, and percent removal calculation for easier, faster TOC monitoring. Available in three models— 5310 C Laboratory, 5310 C On-line, and 5310 C Portable —these low maintenance Analyzers need no external reagents or gas supplies, and offer one-year calibration stability. Key Applications The 5310 C Analyzers monitor raw and finished water TOC for plant optimization, USEPA compliance reporting, and distribution security monitoring applications. They recover the mos tdifficult-to-oxidize organiccom-pounds by combining UV/persulfate oxidation with the proven Sievers Membrane Conductometric Detection Technology, a USEPA-approved methodology under Standard Methods 5310 C and USEPA Method 415.3. The 5310 C specifically calculates Percent TOC Removal in both grab and on-line mode to support Disinfectant and Disinfection By products Rule (D/DBPR) compliance. The 5310C Analyzers offer great flexibility. They can be used for continuous on-line measurement, or to analyze water samples with different sample matrices and concentrations from various points in a plant’s treatment process with the highest efficiency and accuracy. The highly versatile Portable version can be moved between the lab and the plant to facilitate on-line pilot studies and full-scale testing for process optimization. Features and Benefits The 5310 C Analyzers features best-of-class ease of use in setup, operation, and maintenance.
![]() Grab Mode Alphanumberic Labeling Screen Shot ![]() TOC Removal Percentage Protocol and Results
Accessories and Options — On-Line, Portable and Laboratory Models Inorganic Carbon Remover (ICR). The Sievers 900 Inorganic Carbon Remover (ICR*) complies with USEPA-approved methodology for IC removal, and continuously and reliably removes IC from incoming samples. No manual acidification/sparging is necessary and no additional work by the analyst is required. The quiet, compact integrated ICR fits within the 5310 C On-Line Analyzer’s enclosure, or the stand-alone ICR mounts conveniently to the side of the Laboratory or Portable Analyzer. ![]() Picture - Inorganic Carbon Remover (ICR) Pre-Filter Kits(On-Line or Portable only). The Sievers Pre-Filter Kits provide sample streams conditioning of raw water to ensure optimal instrument performance. Two application-specific kits are available: normal use and heavy use. Both provide 40-micron filtration. GE Autosampler + DataPro 5310 C Software (Laboratory and Portable only). For high-volume laboratory applications, the 5310 C can be used with the GE Autosampler. The GE Autosampler provides high throughput sample capacity (up to 63 positions for 40- or 60-mL vials, or up to 120 positions for 35-mL test tubes or 17-mL vials). The Sievers DataPro 5310 C software integrates the GE Autosampler with the 5310 C Laboratory and Portable Analyzers to offer a host of productivity enhancing features, such as automated calibration and verification protocols. DataPro 5310 C also gives users full sampling flexibility with custom sample protocols and user-defined sampling capabilities. The GE Autosampler’s slim 28.2-cm (11.1-in) profile requires minimal bench space. ![]() Picture - GE Autosampler In addition to the GE Autosampler’s vial positions, a standards rack provides an additional six vial positions that can be used to check standards that are typically run with each batch of samples. Through the 5310 C DataPro software, the Autosampler can be programmed to perform a cal check between samples, at a frequency determined by the user. Alternatively, the standards rack can be used for additional sample vial capacity. The GEAutosampler also has an optional rinse station and wash pump that provides a flush of the sample inlet system with a flowing water source. This maximizes analytical performance of sample sets with widely varying concentration.
Specifications — 5310 C Laboratory, On-Line, and Portable Analyzers
The Sievers 900 Series TOC Analyzers are protected by one or more of the following US and foreign patents: US 7247498; US 6271043; US 5976468; US 5837203; US 5443991; EP 0897530; FR 0897530; GB 0897530; DE 69702516.0-08 . Other patents pending. This information herein may be subject to change without notice and is provided for general guidance only. The dimensions and performance of systems, products and services may vary. Pictures are for example purposes and not to scale. All legal obligations are exclusively as set out in contractual documents. Nothing contained herein constitutes a representation, warranty or undertaking. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Views: 1510 | Downloads: 0 | |